The PS Series is a remote power supply line from FireLite Alarms and is a direct replacement for the FCPS-24FS6/8 Series. The FLPS6(C) is a 6 amp and the FL-PS10(C) is a 10 amp, remote power supply with battery charger that may be connected to any 12 or 24 volt fire alarm control panel (FACP) or used as a standalone power supply. The PS Series provides 24 VDC power for NACs (notification appliance circuits) configured as either Class B or Class A (requires the ZNAC-PS option card) with multiple sync protocol options. The PS Series also provides auxiliary power, constant or resettable, suited for detectors, annunciators, door holders, and other fire alarm system peripherals. The PS Series cabinet can hold two 7 AH or 18 AH batteries and can charge up to 33 AH batteries in a separate cabinet.Features Up to five (6 amp model) or seven (10 amp model) independently-configurable, power-limited output circuits for: Class B and/or Class A NACs Class B and/or Class A resettable or non-resettable 24V auxiliary power door holder power Converts from Class B to Class A wiring without losing any outputs using the ZNAC-PS converter card (sold separately) Optimal for powering four-wire smoke detectors, annunciators, and other system peripherals requiring regulated power Configurable for ANSI® Temporal 3 or Temporal 4 coded output UL-Listed NAC synchronization using System Sensor®, Wheelock®, Gentex®, or AMSECO® appliances Synchronization can be triggered from FACP NAC/remote sync outputs, cascaded power supply, or a control module, single or multi, which may be housed within the power supply cabinet Ability to cascade up to four power supplies Two (6 amp model) or three (10 amp model) fully-isolated input/ control circuits which can be programmed to any output Two Form C normally-closed trouble relays for AC Trouble and General Trouble, Ground Fault relay available on Canadian models only 6 or 10 amp full load output, respectively, with 3 A maximum/circuit Individual NAC power and trouble LEDs for diagnostic efficiency Trouble history modes for diagnostic support Wide range end-of-line supervision value (normal: 2K-27K ohms) Selectable earth fault detection (enable or disable) AC trouble report delay timer Completely configurable via onboard DIP switches, no extra software required Self-contained in compact, locking cabinet constructed of heavy gauge steel with a corrosion-resistant powder coat chip and scratch-resistant finish Cabinet designed with ten double knockouts and a removable door for ease of installation and wiring Includes integral battery charger capable of charging up to 33 AH batteries Cabinet can house two 7 AH or 18 AH batteries Battery charger may be disabled via DIP switch for applications requiring larger batteries and external battery charger Removable terminal blocks accommodate up to 12 AWG (3.1mm2) wire Works with any UL 864 FACP which utilizes an industry-standard reverse-polarity notification circuit Optional devices include addressable control, monitor, and relay modules and power-supervision relay (EOLR-1)